6-30
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Troubleshooting
Table 6-2 Power Supply Tap Troubleshooting Chart
3 Phase Power Supply
Single Phase
Supply
Rectifier Board "A"
Rectifier Board "B"
SCRs
Fuses
SCRs
Fuses
SCRs
Fuses
TAP 1
48V
Q13
F13
Q4
F4
CR4
F4
Q17
F17
Q8
F8
CR8
F8
Q21
F21
Q12
F12
TAP 2
50V
Q14
F14
Q3
F3
CR3
F3
Q18
F18
Q7
F7
CR7
F7
Q22
F22
Q11
F11
TAP 3
52V
Q15
F15
Q2
F2
CR2
F2
Q19
F19
Q6
F6
CR6
F6
Q23
F23
Q10
F10
TAP 4
54V
Q16
F16
Q1
F1
CR1
F1
Q20
F20
Q5
F5
CR5
F5
Q24
F24
Q9
F9
Soft Start
Tap
There are no Soft Start SCRs
on Rectifier Board "A"
Q34
F4
Q10
F1
Q35
F8
Q11
F2
Q36
F12
All component numbers should be verified with the schematic.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...