4-4
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
4.2.3.2 Z-Plane Combiner Board
The Combiner Board receives the outputs from the 8 PAs and combines them in two
4 Way Isolated Wilkinson Combiners, whose outputs are then combined in a 2 way
Wilkinson combiner for a 2.5kW nominal output. Each PA is capable of delivering
up to 425 watts into a good load, but will be operating at approximately 325 watts
nominally for 2kW of combined transmitter output. The isolation loads for all 3
combiners are located on another board called the Isolation Board for better heat
dissipation and easier access. The Isolation board is located on the side of the Power
Block nearest the center of the transmitter. The Isolation Board also contains RF
switches which can switch out a faulty PA without causing a severe system
imbalance, allowing greater redundancy. This also allows the PA Modules to be
HOT-PLUGGABLE, meaning that a PA module may be removed while the
transmitter is operating. Interlock pins on the module connectors mute the PAs
before it switches out the unplugged module.
4.2.4
RF output
The 2.5kW output from the Z-Plane passes through an aluminum box under the PA
(in the Power Supply Compartment) and connects to the transmission line
Harmonic Filter at the top rear of this box. The harmonic filter connects to the
output flange on the top rear of the transmitter. The Harmonic Filter has 3
directional couplers. One is for Forward Power, one is for Reflected Power and the
third is left available for on site use as a Demodulator or analyzer sample. The
couplers are designed for at least 30dB directivity.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...