6-2
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Troubleshooting
6.2
Power Amplifier Repair
Field replacement of the MOSFETs on the PAs should NOT be attempted. To repair
a PA requires an extensive amount of test equipment and expertise due to the tight
tolerances allowed for calibration of the test equipment setup and especially for
phase and gain of the PA.
As an additional consideration, please observe the following warning from the
MOSFET manufacturer regarding beryllium oxide.
!
WARNING:
PRODUCT AND ENVIRONMENTAL SAFETY-TOXIC MATERIALS. THIS PRODUCT
CONTAINS BERYLLIUM OXIDE. THE PRODUCT IS ENTIRELY SAFE PROVIDED
THAT THE BEO DISC IS NOT DAMAGED. ALL PERSONS WHO HANDLE, USE OR
DISPOSE OF THIS PRODUCT SHOULD BE AWARE OF ITS NATURE AND OF
THE NECESSARY SAFETY PRECAUTIONS. AFTER USE, DISPOSE OF AS
CHEMICAL OR SPECIAL WASTE ACCORDING TO THE REGULATIONS APPLY-
ING AT THE LOCATION OF THE USER. IT MUST NEVER BE THROWN OUT WITH
THE GENERAL OR DOMESTIC WASTE.
Defective PAs should be exchanged by contacting the Harris, Service Parts
Department (available 24 hours a day 7 days a week).
6.2.1
Transmitter Power vs. Module Failures
The Table below lists the typical best case and worst case power levels for the Z2
and Z2R (Redundancy Package) transmitter due to loss of PAs, removal of PA
Modules (2 PAs) or the loss of a PA controller or Power supply. These power levels
are due to either calculated or actual foldback conditions and may vary quite a bit
due to individual operating conditions.
NOTE:
These are typical power levels operating into a dummy load with mini-
mal VSWR and low ambient temperature. These power levels are not
guaranteed and are given merely as an approximate guideline to aid in
troubleshooting.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...