5-6
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Maintenance and Alignment
NOTE:
The resistors should be ordered as an assembly, with the thermistor already
attached as this is very critical to proper transmitter operation.
5.5.1.2 Installation of Isolation Assembly
If a new Isolation Board is being installed be sure to set the ID jumpers to the proper
location as marked on the PC Board next to the jumper pins. The safest method is to
set the ID the same as the board being replaced.
The Isolation assembly should slide back into place fairly easily as long as none of
the pins are bent. For proper orientation, note the notch on one end of the sheet
metal of the Isolation assembly which fits around the rf drive cable from the IPA.
Re-install the 4 hex standoffs and the 2 ribbon cables, making sure that the cables
are connected to the same port from which they were removed. Be careful not to
over-tighten the hex standoffs.
5.6
PA Replacement
Since field repair of the Power Amplifiers is not a recommended procedure, the
only option is to replace it (especially during the warranty period). A replacement
PA will include the 1/4 inch thick copper plate under the PC board. Do not remove
the PC Board from the copper plate. When installing the new PA, be sure to use a
thermal interface pad, or apply a thin but even coating of thermal compound before
re-assembly to the heatsink. Tolerance on the screw holes will assure alignment into
the Z-Plane connector.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...