888-2406-002
4-59
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
Table 4-1 PA Control Distribution
This chart is meant as an aid in tracking control, status and metering signals between the PA
Controllers and the individual PAs. The first column groups the PAs by Z-Plane. The second
column gives the actual PA designation or location as silkscreened on the inside of the PA
doors. As for the third and fourth colums, the PA Controller is identical and has the ability to
control 8 PAs, PA1-PA8. However, an output labeled PA1 on the PA Controller schematic
does not necessarily go to amplifier 1. For example, note that on the Z-Plane, amplifier 4 is
connected to any input or output labeled PA8 on PAC #1. The fifth column is actually the
intermediate step between the PAs and the PA Controllers and gives the designation and
connector number for each of the PAs. The last 2 columns give the component designator
for the Isolation Switch and Isolation Resistor for each of the PAs. Ths Isolation switches
and resistors are located on the Isolation boards mounted on the side of the Z-Plane.
PA Designations on PA
Controller Schematic
PAC #1
PAC #2
(Z2R Only)
PA Designations
on Combiner and
Divider Schematic
Related
Isolation
Relay #
Related
Isolation
Resistor #
1
PA5
PA5 (J5)
K5
RT5
2
PA6
PA6 (J6)
K6
RT6
3
PA7
PA7 (J7)
K7
RT7
4
PA8
PA8 (J8)
K8
RT8
5
PA4
PA4 (J4)
K4
RT4
6
PA3
PA3 (J3)
K3
RT3
7
PA2
PA2 (J2)
K2
RT2
8
PA1
PA1 (J1)
K1
RT1
PA Designations
Z-PLANE
PA Designations on PA
Controller Schematic
PA Designations
on Combiner and
Divider Schematic
Related
Isolation
Relay #
Related
Isolation
Resistor #
1
PA5 (J5)
K5
RT5
2
PA6 (J6)
K6
RT6
3
PA7 (J7)
K7
RT7
4
PA8 (J8)
K8
RT8
5
PA4 (J4)
K4
RT4
6
PA3 (J3)
K3
RT3
7
PA2 (J2)
K2
RT2
8
PA1 (J1)
K1
RT1
PA Designations
PA2
PA1
PA3
Z-PLANE
PA7
PA8
PA4
PA5
PA6
Standard Z2
Z2R (Redundant Package)
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...