2-26
888-2473-001
2/25/03
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Series™
2.14.1 Transmitter Control Functions, J13 and J14
All control inputs use opto-isolators for surge protection. The opto-isolators are
powered by an in5Vdc from an isolation protection circuit, U54.
All transmitter control functions (except Remote RF Mute) are momentary ground
switching and require the remote control equipment to sink at least 15mA to
activate the function. The Pinouts of J13 and J14 are listed in Table 2-3.
Table 2-3 J13 & J14, External I/O Board, Remote Control Connectors
Connector
Schematic
Label
Function
J13-1
GND
Ground
J13-2
/INPUT 1
REMOTE_ON
J13-3
/INPUT 2
REMOTE_OFF
J13-4
/INPUT 3
REMOTE_RAISE
J13-5
/INPUT 4
REMOTE LOWER
J13-6
GND
Ground
J13-7
GND
Ground
J13-8
/INPUT 5 *
REMOTE_DRA/B_SEL - Remote Drive Chain A/B Select (Toggle)
J13-9
/INPUT 6 *
REMOTE_ASI_1/2_SELECT - ASI Input 1/2 Toggle
J13-10
/INPUT 7
REMOTE_RF MUTE_ON- Transmitter RF output is muted as long
as this input is held low. (High = Un-mute)
J13-11
/INPUT 8
REMOTE_Pump A/B Select
J13-12
GND
Ground
J14-1
GND
Ground
J14-2
/INPUT 9
REMOTE_RF_SW A/B_SELECT
J14-3
/INPUT 10
RF_SW_A_STAT (from 3 port U-Link panel or motorised rf
switch, Antenna position status) Input held low while in antenna
position
J14-4
/INPUT 11
RF_SW_B_STAT (from 3 port U-Link panel or motorised rf
switch, Load Position status) Input held low while in test load
position
J14-5
/INPUT 12
SPARE
J14-6
GND
Ground
J14-7
GND
Ground
J14-8
/INPUT 13
SPARE
J14-9
/INPUT 14
SPARE
J14-10
/INPUT 15
SPARE
J14-11
/INPUT 16
SPARE
J14-12
GND
Ground