6-8
888-2473-001
2/25/03
WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
ATLAS Series™
M# In Overdrv
Module #1-8
RF Input Over-
Drive
Module RF drive input level has
been exceeded
MODULE OFF
YES
M# Out Overdrv
Module #1-8
RF Output Over-
Drive
Module RF output has exceeded
800W
MODULE OFF
YES
M# Heatsink
OT
Module #1-8
Heatsink Over-
Temperature
Module heatsink below pre-driver
has exceeded 70
o
C
MODULE OFF
YES
M# SW Board
OT
Module #1-8
DC Distribution
Board Over-
Temperature
Temperature on DC Distribution
Board has exceeded 90
o
C
MODULE OFF
YES
Table 6-2 Atlas PA Module Fault List
TYPE
Description
Fault Level or Threshold
Transmitter
Action
Three
Strik
e