1-16
888-2473-001
2/25/03
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
ATLAS Series™
Environmental
Operational
Temperature Range
°C
Derate 2
degree C per
300m AMSL
0-45
Operational Relative
Humidity
%
non-condensing
0 - 90
Altitude
meter
s
AMSL
0-4000
Cooling Method
(primary)
%
Liquid cooling
Propylene
Glycol/
Water
50/50
Acoustic Noise
dBA
Measured 1m from front of
cabinet and 1m up from the
floor (does not include
cooling pump module and
heat exchanger)
<65
Residual Heat
transferred to room
kW
Maximum per transmitter
cabinet with 8PAs
< 3.9
Physical
Dimensions
mm
Single Cabinet Transmitter
DVL400 thru
DVL3000
700W x
1980H x
1040D
Dual Cabinet Transmitter
DVL4300 &
DVL5700
1400W x
1980H x
1040D
Weight
Kg
Weight includes all options
Model
Weight
DVL400
303
DVL800
330
DVL1100
365
DVL1500
399
DVL2200
463
DVL3000
526
DVL4300
894
DVL5700
1020
"Note: Unless otherwise noted, these specifications apply at the output of a Harris supplied mask
filter."
Table 1-2 Atlas Performance Specifications
Item
Units
Conditions
Notes
Value
Summary of Contents for Atlas DVL400