2/25/03
888-2473-001
4-37
WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
ATLAS Series™
Table 4-3 PS Monitor, Analogue Measurements and Scaling
Ref. #
Signal
Scale
Description
1
Phase A
400vac = 3.0vdc
AC Primary voltage
2
Phase B
400vac = 3.0vdc
AC Primary voltage
3
Phase C
400vac = 3.0vdc
AC Primary voltage
4
Average ac
400vac = 3.0vdc
(AB+BC+CA)/3
5
REV_VOLT
Rev A = 0v
0.25v increment/Rev
Micro Module Revision
6
PS1_+7.5v
7.5vdc = 3.0vdc
PS1 +7.5v output
7
PS1_+15v
15vdc = 3.0vdc
PS1 +15v output
8
PS1_-15v
-15vdc = 3.0vdc
PS1 -15v output
9
PS2_+7.5v
7.5vdc = 3.0vdc
PS2 +7.5v output
10
PS2_+15v
15vdc = 3.0vdc
PS2 +15v output
11
PS2_-15v
-15vdc = 3.0vdc
PS2 -15v output
12
SPARE
13
SPARE
14
+7.5v
7.5vdc = 3.0vdc
Or'ed output of PS1 & PS2
15
+15v
15vdc = 3.0vdc
Or'ed output of PS1 & PS2
16
-15v
-15vdc = 3.0vdc
Or'ed output of PS1 & PS2
17
+3.3v
3.3v = 3.3vdc
3.3 volt regulator output
18
+5v
5v = 3.0vdc
5 volt regulator output
19
+12v
12v = 3.0vdc
12 volt regulator output
20
-12v
-12v = 3.0vdc
-12 volt regulator output
21
Vref
4.096v = 3.0vdc
Output of on board reference
22
Air Temperature
32mv / Deg C
0 Deg C = 1.6v
Ambient temperature sensor located on PS
Monitor board
23
Air Pressure
-1"H2O = .25vdc
0"H2O = 2.25vdc
+1"H2O = 4.25vdc
Air Pressure - Fan(s) OK