1-4
888-2473-001
2/25/03
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
ATLAS Series™
1.2.2
System Block Diagrams
The following figures contain System block diagrams showing the basic signal flow
and configuration for each Atlas Series™ Transmitter Model. Figure 1-2 shows the
Medium Power single cabinet system with up to 8 PA modules. Note that a driver is
not needed, as the exciter power is sufficient to drive up to 8 PA modules. Figure 1-
3 shows the High Power configuration which is simply the addition of a second
cabinet and a cabinet combiner for outputs of 4.3Kw and 5.7kW.
Figure 1-2 Atlas Series™ Medium Power System Block Diagram
400W up to 3kW (DVL 3000 shown)
Exciter A
Exciter B
Drive
Control
Unit
RF Monitor
DVB
Filter
Reject
Loads
PA 1
PA 2
PA 3
PA 4
PA 5
PA 6
PA 7
PA 8
PS 1
32V
PS 2
32V
PS 3
32V
PS 4
32V
Ext
I/O
Board
Main
Controller
&
Life Support
MOV
Board
LVPS
LVPS
AC Power
380/400/415
VAC 3-Phase
or
220/240
Single Phase
To PA Modules
Bus to 2nd PA
TCP/IP
RS-232
Parallel
Ext Interlocks
Pump Control
ASI-1
ASI-2
10MHz
GPS
1 PPS
ASI-1
ASI-2
10MHz
GPS
1 PPS
1-5/8” Line
Model: DVL 3000
3.4kW
3.0kW
460W
460W
460W
460W
460W
460W
460W
460W
Power Supply Monitor
PS Control and Monitoring
Graphical
User
Interface
RF Samples
Note: This represents Cabinet #1
for the DVL 4300 and 5700
RF Splitter
RF Combiner
PA Cabinet FWD and RFLD
Total System FWD and RFLD
These Components are outside
the Transmitter Cabinet