WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Series™
3.8.1
PS Faults
This screen is Power Supply status screen which lists of all of the monitored power
supply faults for the AC Mains and Low Voltage Power Supplies. An active fault
will be highlighted in RED, while a warning condition will be highlighted in
YELLOW. For a detailed explanation of these faults, refer to Section 6,
Diagnostics.
Figure 3-27 PS Faults Screen
3.8.2
PS Meters
This is the detailed metering screen for the AC Mains, PA PS and LV PSU. For
multiple cabinet transmitters, be sure to note which cabinet is being monitored.
NOTE:
The PA PS voltages can vary several volts (approximately 27 to 33Vdc)
depending on the selected frequency. This is done to optimise the PA Module
efficiency. This is an automatic function and cannot be changed by the user.
Figure 3-28 PS Metering Screen
To Figure 3-26
To Figure 3-20
Cabinet Being
Monitored
See Note Above