Chapter 7 Device Configuring Using EMS
Multiplex Inputs
© 2012 Harmonic Inc.
93
ProView 7000 v.2.6, Rev. E
The Multiplex In Port dialog comprises:
■
General box
❑
Enabled
– Use to enable or disable the multiplex input.
❑
Transport Stream ID
– Displays the transport stream’s ID.
❑
Table Extraction
– Use to select
PSI/SI
for DVB or
PSI
for MPEG. For ATSC systems, set the
stream type to MPEG. The default is
PSI/SI
.
❑
Assigned CAMs
– Displays CAM slots assigned to the multiplex input.
❑
Primary Source Port
– Use to select the primary physical input port for the multiplex
input.
■
Input Redundancy box
❑
Redundancy Mode
❑
Backup Source Port
❑
Active Port
❑
Redundancy Triggers
• MPEG Sync Loss Alarm tab
· Trigger Alarm – use to enable or disable the trigger, default is
Enable
.
· Primary Port Event Duration – set the period that the state must exist to trigger
redundancy
· Backup Port Event Duration – set the period that the state must exist to trigger
redundancy
• CC Errors Alarm tab
· Trigger Alarm – use to enable or disable the trigger, default is
Enable.
· Primary Port Number of Errors – set the number of CC errors that must occur within
a period to trigger redundancy
· Primary Port Within – set the period that the number of CC errors must occur
within to trigger redundancy
· Backup Port Number of Errors – set the number of CC errors that must occur within
a period to trigger redundancy
· Backup Port Within – set the period that the number of CC errors must occur within
to trigger redundancy
• PID Missing Alarm tab
· Trigger Alarm – use to enable or disable the trigger, default is
Enable.
· PID – set the PID number
· Primary Port Missing For – set the period that the PID must be missing for to trigger
redundancy
· Backup Port Missing For– set the period that the PID must be missing for to trigger
redundancy