Chapter 7 Device Configuring Using EMS
Physical Input Ports and Slots
© 2012 Harmonic Inc.
81
ProView 7000 v.2.6, Rev. E
■
IP Profile
– Enables you to configure the following:
❑
IP Address
– Each port must have a different IP Address. The default is
127.127.0.X
,
where X is the port number.
❑
Mask
– The IP mask. The default is
255.255.255.0
.
❑
MAC Address
– Each port has its own MAC Address. They are factory set and cannot be
changed.
Figure 7–2: GbE Port Properties dialog - General tab
GbE Port Advanced properties tab:
■
Autonegotiation Enabled
– You can enable and disable Autonegotiation. The default is
Yes
.
■
Duplex Mode
– You cannot change the Duplex Mode. It is fixed at Full Duplex.
■
Speed
– You can configure the PHY speed when Autonegotiation is disabled. The default is
1000
.
Figure 7–3: GbE Port Properties dialog - Advanced tab