Chapter 4 Device Configuring Using the Front Panel
Configuring the GbE Ports, Sockets and Routing Table
© 2012 Harmonic Inc.
50
ProView 7000 v.2.6, Rev. E
4.4
Configuring the GbE Ports, Sockets and Routing Table
Use the GbE menu to configure the GbE ports, MPE PID, sockets and routing table.
To access the GbE menu:
❖
Navigate
Root > GbE
.
The GbE menu has the following sub-menus:
■
GbE Port 1/2
– Use these menus to configure the following:
❑
IP Configuration – Use this menu to configure the following:
• IP Address – The default is
127.127.0.X
(X is the port number). Each port must have a
unique IP address.
• Subnet Mask – The default is
255.255.255.0
.
• Gateway – Output only. The default is
127.127.0.1
.
❑
MAC Address – Use this menu to view the MAC address for this port.
❑
Admin Status – Use this menu to view or set the Admin Status to one of the following:
•
Up
– Enable
•
Down
– Disable
If Admin Status is set to
Up
and no link is detected, a no link alarm is raised. The default
is
Down
.
❑
Auto Negotiation – Use this menu to view the Auto Negotiation status or set it to one of
the following:
• On
• Off
The default is
On
.
❑
PHY Speed – Use this menu to view the PHY speed. When Auto Negotiation is off you can
change PHY Speed to one of the following:
• 100
• 1000
The default is
1000
.
❑
Duplex Mode – Only Full Duplex Mode is supported.
■
MPE
13
– Use the MPE menu to configure one MPE PID source for GbE out. There are three
service selection modes, Program, PID and Disabled.
The MPE menu comprises the following sub-menus:
❑
Mode:
• Program – Use this mode to configure an MPE PID by entering the program ID. The PID
is configured automatically.
• PID – Use this mode to configure an MPE PID by entering the PID.
• Disabled
❑
Input Port – Use this menu to select the multiplex input.
❑
Program Number – This menu only displays in Program mode.
13. Requires a license.