Appendix E ProView 7000™ Alarm List
© 2012 Harmonic Inc.
196
ProView 7000 v.2.6, Rev. E
Demodulation Failure
Critical
No carrier was detected in the configured frequency.
Verify the following is properly configured:
■
Modulation Standard
■
Spectral Inversion
■
MODCOD
■
Frame Size
■
Pilot Symbols
■
Physical Layer Scrambling Seed
DSR not synced
Major
■
Verify that the relevant inputs are connected correctly.
■
If the problem persists, contact the Harmonic help desk.
Eb/N0 Value Too Low
Warning
Verify reception conditions and wiring.
Embedded descrambler
overflow
Major
Reduce the bitrate or bypass the embedded descrambler.
ES Decoding Failure –
Unsupported Content
Major
Contact Harmonic’s help desk.
Ethernet Auto Negotiation
Failure
Major
Ethernet Auto-negotiation has failed.
Verify that the cable if properly wired or consider reverting to
manual PHY speed configuration.
Fan Failure
Major
Contact Harmonic’s help desk for further support.
Firmware download
failure.
Warning
Verify that the correct file was selected and there are no network
disconnections.
Firmware upgrade failure.
Previous version loaded.
Warning
Upgrade again or revert to the previous version.
Frame Rate Mismatch.
Warning
The configured video frame rate does not match the frame rate
of the source.
Re-configure the decoding frame rate.
GbE Backup Port
Activated
Warning
The GbE backup port has been activated. Revert to GbE-1 as
soon as possible.
GbE Input Port Failed
Critical
Both GbE inputs failed.
■
Verify that the cables are connected properly at both ends.
■
Verify that the ports at both ends are enabled.
■
Change the redundancy mode.
High Temperature
Warning
Major
Make sure the fans are operating and are not blocked, if the
warning remains:
1. Turn off the device.
2. Contact Harmonic’s help desk.
Input bitrate overflow
Major
The input bitrate to the decoder is too high. Contact Harmonic’s
help desk.
Input bitrate overflow on
CAM
Major
The input bitrate to the CAM is too high.
■
Reduce the input bitrate.
■
Contact Harmonic’s help desk.
Short Description
Severity
Corrective Action