Operations Manual SC-610
Page 21
Harmonic Drive AG
900105
11/2005
4.1.5 Regeneration Resistor Wiring
The regeneration resistor can be installed by the user (see chapter 4.3). If during normal operation
fault "1"
occurs (overvoltage; see chapter 6), a regeneration resistor must be connected to the
controller
to over-
come this problem. For regeneration resistor installation the recommendations below should be observed.
Selection table:
Regeneration Power
continuous
[W]
Regeneration-
resistor value
[
Ω
]
Power
supply
[VAC]
Regeneration-
Switching
current
[A]
Harmonic
Drive-
Order-No.
44 56
230
7
700889
100 39
230
10
701121
1): Duty cycle = 2% at T = 120s
The generation resistor is not automatically included in the
delivery.
The generation resistor must be mounted horizontal on a
vertical surface for full power rating.
For vertical mounting on a horizontal surface the nominal load
capacity is reduced to 65%.
Take care of good cooling of the regeneration resistor.
The ambient temperature of the resistor can be up to 200°C, in
a distance of 30mm.
Keep a safe distance between regeneration resistor and
flammable materials. The mounting surface can reach a
temperature of 80°C.
Wiring:
The resistor must be wired with a 2 lead (2,5 mm
2
) screened cable. The resistor housing must be grounded.
Summary of Contents for SC-610 Series
Page 1: ...Operations Manual AC Servo Controller SC 610 No 900105 11 2005 24 11 2005 FA...
Page 3: ......
Page 52: ...Operations Manual SC 610 Page A1 Harmonic Drive AG 900105 11 2005 APPENDIX...
Page 64: ...Operations Manual SC 610 Page A13 Harmonic Drive AG 900105 11 2005 APPENDIX G...
Page 65: ...Page A14 Operations Manual SC 610 Harmonic Drive AG 900105 11 2005 APPENDIX H...
Page 66: ...Operations Manual SC 610 Page A15 Harmonic Drive AG 900105 11 2005 APPENDIX I...
Page 67: ...Page A16 Operations Manual SC 610 Harmonic Drive AG 900105 11 2005 APPENDIX J...
Page 68: ...Operations Manual SC 610 Page A17 Harmonic Drive AG 900105 11 2005 APPENDIX K...
Page 69: ......