Command Manual (For Soliton) – System Maintenance and Debugging
H3C S3100 Series Ethernet Switches
Chapter 3 Device Management
Commands
3-4
3.1.5 display device
Syntax
display device
[
manuinfo
|
unit unit-id
]
View
Any view
Parameter
manuinfo
: Specifies to display the manufacture information of the specified switch.
unit-id
: Unit ID of a switch, the value can only be 1.
Description
Use the
display device
command to display the information, such as the module type
and operating status, about each board (main board and sub-board) of a specified
switch.
You can use this command to display the following information about each board,
including slot number, sub-slot number, the number of ports, versions of PCB, FPGA,
CPLD and Boot ROM software, address learning mode, interface board type, and so
on.
Example
# Display board information of this switch.
<Sysname> display device
Unit 1
SlotNo SubSNo PortNum PCBVer FPGAVer CPLDVer BootRomVer AddrLM Type State
0 0 24 REV.A NULL 001 506 IVL MAIN Normal
0 1 1 REV.A NULL NULL NULL IVL COMBO TBD Normal
0 2 1 REV.A NULL NULL NULL IVL COMBO TBD Normal
Table 3-3
Description on the fields of the
display device
command
Field
Description
SlotNo
Serial number of the slot
SubSNo
Serial number of the sub slot
PortNum
Number of ports
PCBVer
Version number of the PCB card
FPGAVer
Version number of the FPGA encapsulation
CPLDVer
Logical version number of the hardware CPLD
BootRomVer
Version number of the Boot ROM