Command Manual (For Soliton) – GVRP
H3C S3100 Series Ethernet Switches
Chapter 1 GVRP Configuration Commands
1-3
z
Leave timer
z
LeaveAll timer
z
Hold timer
Related commands:
garp timer
,
garp timer leaveall
.
Examples
# Display the settings of the GARP timers on port Ethernet1/0/1.
<Sysname> display garp timer interface Ethernet 1/0/1
GARP timers on port Ethernet1/0/1
Garp Join Time : 20 centiseconds
Garp Leave Time : 60 centiseconds
Garp LeaveAll Time : 1000 centiseconds
Garp Hold Time : 10 centiseconds
1.1.3 garp timer
Syntax
garp timer
{
hold
|
join
|
leave
}
timer-value
undo garp timer
{
hold
|
join
|
leave
}
View
Ethernet port view
Parameters
hold
: Sets the GARP Hold timer.
join
: Sets the GARP Join timer.
leave
: Sets the GARP Leave timer.
timer-value
: Timeout time (in centiseconds) of the GARP timer (Hold, Join or Leave) to
be set.
Description
Use the
garp timer
command to set a GARP timer (that is, the Hold timer, the Join timer,
or the Leaver timer) for an Ethernet port.
Use the
undo garp timer
command to restore the default setting of a GARP timer.
By default, the Hold, Join, and Leave timers are set to 10, 20, and 60 centiseconds.
Note that:
z
The setting of each timer must be a multiple of 5 (in centiseconds).