Command Manual (For Soliton) – DLDP
H3C S3100 Series Ethernet Switches
Chapter 1 DLDP Configuration Commands
1-5
Parameter
timer-value
: Interval for sending DLDP advertisement packets, in the range 1 to 100 (in
seconds).
Description
Use the
dldp interval
command to set the interval for sending DLDP advertisement
packets for all DLDP-enabled ports in the advertisement state.
Use the
undo dldp interval
command to restore the default.
By default, the interval for sending DLDP advertisement packets is 5 seconds.
Note that:
z
The interval takes effect on all the DLDP-enabled ports.
z
It is recommended that you set the interval shorter than one-third of the STP
convergence time (usually 30 seconds). If too long an interval is set, an STP loop
may occur before DLDP shuts down unidirectional links. On the contrary, if too
short an interval is set, network traffic increases, unnecessarily consuming port
bandwidth.
Example
# Set the interval for sending DLDP advertisement packets to 6 seconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] dldp interval 6
1.1.5 dldp reset
Syntax
dldp reset
View
System view, Ethernet port view
Parameter
None
Description
In system view:
Use the
dldp reset
command to reset the DLDP status of all the ports disabled by
DLDP.
In Ethernet port view: