Engineering Data
6
Bearing
Default-Non-bearing water tank;
C-Bearing water tank
7
Type of Heat Exchange Tube
Default-No heat exchanger;
J-Inner coil static heating(J-Single coil; J2-Double coils);
JW-Outer coil static heating
8
Serial Number
A,B,C……
9
Power Supply
K=220-240V,~,50Hz; M=380-415V,3N~,50Hz; H=380V,3N~,60Hz
1.3 Product Features
1.3.1 General
It‘s a kind of integrated DC inverter unit that comprises cooling, heating and water heating functions,
and up to 5.0 energy efficiency. It adopts R32 refrigerant and two-stage compressor. For heating,
ambient temperature range is -25~35
℃
while the leaving water temperature range is 25~60
℃
.
The Versati
Ⅲ
unit is designed specially for the European market where there is a demand for
high-temperature water. Thanks to the dual-stage compression and enthalpy gain through gas injection,
the heating energy efficiency at low temperature will rise up greatly with the leaving water temperature
up to 60°C. The whole series of products strictly comply with EN14511,EUROVENT energy efficiency
Class A and SCOP class A+++(35
℃
), SCOP class A++(55
℃
) with EN14825. Their COP can reach up to
5.0. This unit can realize space heating and sanitary hot water supply through terminal units, like the fan
coil unit, floor coil and radiator. Environment-friendly refrigerant R32 is adopted for the unit, with ODP of
0 and quite low GWP (=675). Besides, the adopted heat pump technologies will reduce consumption of
coal and other energy source and lower greatly CO2 emission. Ranged from 4.0kW~16kW, it is widely
applicable to small and medium-sized apartment, large-sized villa etc.
1.3.2 Features
Wide Operation Range
Heating: -25~35°C; Cooling: 10~48°C; Water Heating: -25~45°C
Unique Low-Temp Hi-heat Dual-stage Compressor
1. Under low-temperature conditions, compared with the conventional compressor, the dual-stage
low-temp hi-heat compressor will generate less loss of heat capacity and get higher energy efficiency.
2. Floodback, high discharge temperature and other problems can be completely avoided under
low-
temp conditions and the compressor‘s reliability will be enhanced greatly.
3. Dual-stage compression, dual-stage throttling and intermediate enthalpy adding through gas
injection will raise the leaving water temperature and improve the control accuracy.
High-efficiency Component(Inverter pump, Inverter fan, Plate heat exchanger)
Summary of Contents for VERSATI III Series
Page 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Page 5: ...Engineering Data ENGINEERING DATA ...
Page 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Page 22: ...Design and Selection DESIGN SELECTION ...
Page 33: ...Unit Control UNIT CONTROL ...
Page 72: ...Unit Control ...
Page 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Page 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Page 80: ...Unit Control ...
Page 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Page 82: ...Installation UNIT INSTALLATION ...
Page 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Page 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Page 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Page 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Page 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Page 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Page 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...