Unit Control
Time&Data Page
★
2. The mouse rol
ler can change the date and time value. After it, by touching the ―
Save
‖ icon, this
setting will be saved and directly displayed; while by touching the ―
Back
‖ icon, this setting will give
up and the control panel will directly go back to the ―
GENERAL
‖ setting page.
Time&Data Page
3.3 Intelligent Control
[Notes]:
● Make sure the smart phone or tablet computer adopts standard Android or Ios operation system. For
detailed version, please refer to the APP.
● The Wi-Fi function doesn‘t support Chinese Wi-Fi network name.
● The devices can be connected and controlled only in Wi-Fi and 4G hotspot modes.
● Router with WEP encryption is not supported.
● Software operation interface is universal and its control functions may not be completely
corresponding to the unit. Software operation interface may vary along with APP upgrading or different
operation system. Please refer to the actual program.
3.3.1 Installationof the Ewpe Smart APP
[Operation Instructions]
★
1. Scan the following QR code with your smart phone to download and install Ewpe Smart APP
directly.
Summary of Contents for VERSATI III Series
Page 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Page 5: ...Engineering Data ENGINEERING DATA ...
Page 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Page 22: ...Design and Selection DESIGN SELECTION ...
Page 33: ...Unit Control UNIT CONTROL ...
Page 72: ...Unit Control ...
Page 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Page 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Page 80: ...Unit Control ...
Page 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Page 82: ...Installation UNIT INSTALLATION ...
Page 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Page 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Page 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Page 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Page 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Page 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Page 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...