Engineering Data
1. The A-class high-efficiency inverter water pump which complies with the European ErP directive,
can control the running frequency based on the actual load. Therefore, it can enhance the operation
effcieicy and control the water temperature more accurately.
2. The DC inverter fan can control the air volume accuratately and make the system run more stably
and save more energy.
3. The high-
efficiency plate heat exchaner will improve the unit‘s performance largely.
All-in-one Design
1. The unit can integrate with terminal units, like the radiator, floor heating device, FCU, water heating
device, solar kit, gas furnace etc. Versatile functions can meet various kinds of demands from different users
and enhance applicability of this product.
2. The all-in-one structure design can save more installation cost, reduce risks of refrigerant leak, and
improve safety and reliability of the system.
Brand-new Controller
1. White appearance, exquisite design, and the wall-mounted design will facilitate installation.
2. liquid crystal display and touch-screen operation
3. The 12V JACK interface can supply power to the control separately and lengthen the communication
distance.
4. The remote monitoring interface can monitor the unit through the Mobus interface and be integrated
into the BMS system.
Smart Control, Powerful Function
1. The running mode can be switched freely. Furthermore, based on different demands, the holiday
mode, weather-dependent mode, quite timer, temperature timer and floor commissioning can activated.
2. Multiple protections can make this product much safer. The added electric heater will prevent the
plate heat exchanger from being frostbitten owing to too low water temperature and resultantly extend
the service life of the product and enhance its safety and reliability.
3. The newly developed smart defrosting control program, ―do defrost when necessary; do not
defrost when unnecessary; defrost more when it frosts heavily; defrost less wh
en it frosts lightly‖, can
bring more comfortability, avoid inadequacy of heat supply and ensure sustainable heat supply for the
users.
Summary of Contents for VERSATI III Series
Page 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Page 5: ...Engineering Data ENGINEERING DATA ...
Page 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Page 22: ...Design and Selection DESIGN SELECTION ...
Page 33: ...Unit Control UNIT CONTROL ...
Page 72: ...Unit Control ...
Page 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Page 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Page 80: ...Unit Control ...
Page 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Page 82: ...Installation UNIT INSTALLATION ...
Page 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Page 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Page 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Page 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Page 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Page 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Page 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...