Engineering Data
1.1.2 Water Tank
Model
Product Code
Nominal Cubage(L)
Appearance
SXVD200LCJ/A-K
ER20000160
200
SXVD200LCJ/A-M
ER20000240
200
SXVD300LCJ/A-K
ER20000180
300
SXVD300LCJ/A-M
ER20000250
300
SXVD200LCJ2/A-K
ER20000170
200
SXVD200LCJ2/A-M
ER20000260
200
SXVD300LCJ2/A-K
ER20000190
300
SXVD300LCJ2/A-M
ER20000270
300
1.2 Nomenclature
1.2.1 Main Unit
G
RS
-
C
Q
14
Pd
/
Nh
D
-
M
1
2
3
4
5
6
7
8
9
NO.
Description
Options
1
GREE
G-GREE Air to water heat pump
2
Heat Pump Water Heater
RS
3
Heating Mode
S= Static; C=Circulating
4
Function
Q=Multi-function; Omit=Single-function
5
Nominal Heating Capacity
6.0=6.0kW; 8.0=8.0kW;10=10kW; 12=12kW; 14=14kW; 16=16kW
6
Compressor Style
Pd=DC Inverter; Omit=On/Off
7
Refrigerant
Nh=R32
8
Design Serial Number
B,C,D......
9
Power Supply
K=220-240V,~,50Hz; M=380-415V,3N~,50Hz;H=380V,3N~,60Hz
10
Indoor and Outdoor Unit Code
I=Indoor unit; O=Outdoor unit
1.2.2 Water Tank
SX
V
D
200
L
C
J2
/
A
-
K
1
2
3
4
5
6
7
8
9
NO.
Description
Options
1
Symbol of Heat Pump Water Tank
SX
2
Tank Type
Default-Common heat pump water tank;
V-Heat pump water tank for multi VRF system
3
Function Code
Default-No electric heating function;
D-Electric heating function available
4
Nominal Water Tank Volume
200=200L,300=300L
5
Structure Type
B-Wall mounted type; L-Floor standing type
Summary of Contents for VERSATI III Series
Page 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Page 5: ...Engineering Data ENGINEERING DATA ...
Page 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Page 22: ...Design and Selection DESIGN SELECTION ...
Page 33: ...Unit Control UNIT CONTROL ...
Page 72: ...Unit Control ...
Page 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Page 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Page 80: ...Unit Control ...
Page 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Page 82: ...Installation UNIT INSTALLATION ...
Page 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Page 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Page 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Page 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Page 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Page 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Page 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...