Installation
4.17 Wiring of the Thermostat
Installation of the thermostat is very similar to that of the remote air temperature sensor.
How to Wire Thermostat
(1) Uncover the front cover of indoor unit and open the control box ;
(2) Identify the power specification of the thermostat,it is 230V, find terminal block XT4 as
NO.23~26;
(3) If it is the heating/cooling thermostat, please connect wire as per the figure above.
CAUTION!
①
220V power supply can be provided to the thermostat by the Versati III heat pump.
②
Setting temperature by the thermostat(heating or cooling) should be within the temperature
range of the product ;
③
For other constrains, please refer to previous pages about the remote air temperature sensor;
④
Do not connect external electric loads. Wire 220V AC should be used only for the electric
thermostat;
⑤
Never connect external electric loads such as valves, fan coil units, etc. If connected, the
mainboard of the unit can be seriously damaged;
⑥
Installation of the thermostat is very similar to that of the remote air temperature sensor.
4.18 Wiring of the Control
Notes:
①
The wired controller can be connected to the terminal of AP1 CN4 with the four-wire
communication cable.
Monobloc
Unit
AP1
CN4
D
is
p
la
y
B
o
a
rd
R
E
D
Summary of Contents for VERSATI III Series
Page 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Page 5: ...Engineering Data ENGINEERING DATA ...
Page 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Page 22: ...Design and Selection DESIGN SELECTION ...
Page 33: ...Unit Control UNIT CONTROL ...
Page 72: ...Unit Control ...
Page 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Page 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Page 80: ...Unit Control ...
Page 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Page 82: ...Installation UNIT INSTALLATION ...
Page 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Page 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Page 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Page 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Page 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Page 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Page 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...