Engineering Data
1.5 Technical Data
1.5.1 Parameter List
Model
GRS-CQ4.0Pd/
NhG-K
GRS-CQ6.0Pd
/NhG-K
GRS-CQ8.0Pd
/NhG-K
GRS-CQ10Pd/
NhG-K
Product Code
ER01001350
ER01001360
ER01001370
ER01001410
Capacity*
1
Cooling(floor cooling)
kW
3.8
5.8
6.8
8.8
Heating(floor heating)
kW
4
6
7.5
10
Power
Input*
1
Cooling(floor cooling)
kW
0.82
1.26
1.55
1.96
Heating(floor heating)
kW
0.78
1.20
1.63
2.15
EER*
1
(floor cooling)
W/W
4.65
4.6
4.4
4.5
COP*
1
(floor heating)
W/W
5.1
5.0
4.6
4.65
Capacity*
2
Cooling(for Fan coil)
kW
3
4
5
7.8
Heating(Fan coil or
Radiator)
kW
4
6
7.5
10
Power
Input*
2
Cooling(for Fan coil)
kW
0.94
1.27
1.56
2.48
Heating(Fan coil or
Radiator)
kW
0.98
1.56
2.00
2.67
EER*
2
(for Fan coil)
W/W
3.2
3.15
3.2
3.15
COP*
2
(Fan coil or Radiator)
W/W
4.1
3.85
3.75
3.75
Refrigerant charge volume
kg
0.87
2.2
Sanitary water Temperature
℃
40~80
℃
Sound
Pressure
Level
cooling
dB(A)
56
59
heating
dB(A)
58
61
Dimension
s
(W×D×H)
Outline
mm
1150×390×756
1200×460×878
Packaged
mm
1250×480×765
1245×545×885
Net weight/Gross weight
kg
96/109
151/166
Model
GRS-CQ12Pd/
NhG-K
GRS-CQ14Pd/
NhG-K
GRS-CQ16Pd/
NhG-K
GRS-CQ10Pd/
NhG-M
Product Code
ER01001400
ER01001390
ER01001380
ER01001420
Capacity*
1
Cooling(floor cooling)
kW
11
12.5
14.5
8.8
Heating(floor heating)
kW
12
14
15.5
10
Power
Input*
1
Cooling(floor cooling)
kW
2.56
3.05
3.82
1.96
Heating(floor heating)
kW
2.64
3.22
3.60
2.15
EER*
1
(floor cooling)
W/W
4.2
4
3.7
4.5
COP*
1
(floor heating)
W/W
4.55
4.35
4.30
4.65
Summary of Contents for VERSATI III Series
Page 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Page 5: ...Engineering Data ENGINEERING DATA ...
Page 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Page 22: ...Design and Selection DESIGN SELECTION ...
Page 33: ...Unit Control UNIT CONTROL ...
Page 72: ...Unit Control ...
Page 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Page 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Page 80: ...Unit Control ...
Page 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Page 82: ...Installation UNIT INSTALLATION ...
Page 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Page 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Page 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Page 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Page 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Page 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Page 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...