JUPITER L-S and LCD Series Control Panel Instruction Manual
61
Control Panel Sets
Output Set
- Output Set name. Creation of CP Output Sets is described in the
Jupiter CM-4000 Installation and Operating Manual
.
•
For an S25 or S50 panel, with entry of a single Destination name, the
panel will operate as a one-Destination panel. The eight-button cluster
on the right-hand side of the panel will be used to control the first eight
levels of the router.
•
For an S25 or S50 panel, with selection of an Output Set with two, three,
or four Destinations defined, the panel will operate as a two-, three-, or
four-Destination panel respectively. With respect to the eight-button
cluster on the right-hand side of the panel, the top row of four buttons
will be used to select the Destination; the bottom row of four buttons
will be used to control the first four levels of the router.
•
For an S25 or S50 panel, with selection of an Output Set with five, six,
seven, or eight Destinations defined, the panel will operate as a five-,
six-, seven-, or eight-Destination panel respectively. The eight-button
cluster on the right-hand side of the panel will be used to select the Des-
tination.
•
For all other L-S series panels, if an actual CP Output Set is selected,
then the control panel will be able to control all the Destinations listed
in that Set; depending on the contents of the set, this would allow for
full-matrix or multi-bus control. Alternatively, this field can be used to
enter the name of a single switcher Destination to be controlled; the
Source of the Destination name is the Switcher Output table.
Out Panel
- This column is not used for L-S panels.
Level Set
- Select the CP Level Set name.
Override Set
- (Does not apply to S25 and S50. Optional for all other L-S
panels.) Select a CP Override set name. A CP Override set can be used to
define a set of Sources and level combinations that can be quickly applied
to a panel controlled Destination. Up to 10 pages of overrides (80 total) may
be defined. The order in which the overrides are listed on the CP Override
set table will be the order in which they appear on the panel.
Sequence Set
- Select a CP Sequence set name. A Sequence set is used to
execute a list of switches with a single command. (Does not apply to S25
and S50and is optional for all other L-S panels.)
Control Panel Sets
Switcher Sources and Destinations for the L-S panels are specified by cre-
ating a Jupiter CP Level Set, a CP Input Set, and a CP Output Set. These sets
are assigned to each panel using the MPK Devices table (
Summary of Contents for JUPITER CONTROL PANEL L32 -
Page 12: ...12 JUPITER L S and LCD Series Control Panel Instruction Manual Contents ...
Page 14: ...14 JUPITER L S and LCD Series Control Panel Instruction Manual Preface ...
Page 30: ...30 JUPITER L S and LCD Series Control Panel Instruction Manual Regulatory Notices ...
Page 156: ...156 JUPITER L S and LCD Series Control Panel Instruction Manual Section 7 LCD Introduction ...
Page 164: ...164 JUPITER L S and LCD Series Control Panel Instruction Manual Section 10 LCD Configuration ...
Page 206: ...206 JUPITER L S and LCD Series Control Panel Instruction Manual Glossary ...
Page 216: ...216 JUPITER L S and LCD Series Control Panel Instruction Manual Index ...