JUPITER L-S and LCD Series Control Panel Instruction Manual
43
Network Wiring
Network Wiring
The L-S series panels are connected to the CM-4000 System Controller via
Ethernet or a Serial connection. Maximum length of a LAN (Cat5 cable)
connection is 329 feet (100 meters). The LAN must be capable of per-
forming 100 Mb operations, and each Ethernet segment (hub to panel) has
a 100 meter limit. See
Figure 11. LAN only system connections.
Button Labels
Most L-S series panels are supplied with “typical use” button labels already
installed. Additional buttons can be labeled in the field. Two resources are
available for labels:
•
A pre-printed/pre-cut transparency keycap label sheet is supplied with
each panel. See
.
•
Microsoft Word files are available for creating custom labels. For more
information, contact Grass Valley Technical Support.
LAN 1 (Cat 5 Ethernet) cable.
Max. recommended length per
segment = 100 meters (329 ft)
CM-4000
System
Controller
(AccuSwitch)
100baseT Jupiter LAN
to Jupiter
File Server
64 LAN-operated
L-S panels per CM
maximum
8536_08
IP switch
Summary of Contents for JUPITER CONTROL PANEL L32 -
Page 12: ...12 JUPITER L S and LCD Series Control Panel Instruction Manual Contents ...
Page 14: ...14 JUPITER L S and LCD Series Control Panel Instruction Manual Preface ...
Page 30: ...30 JUPITER L S and LCD Series Control Panel Instruction Manual Regulatory Notices ...
Page 156: ...156 JUPITER L S and LCD Series Control Panel Instruction Manual Section 7 LCD Introduction ...
Page 164: ...164 JUPITER L S and LCD Series Control Panel Instruction Manual Section 10 LCD Configuration ...
Page 206: ...206 JUPITER L S and LCD Series Control Panel Instruction Manual Glossary ...
Page 216: ...216 JUPITER L S and LCD Series Control Panel Instruction Manual Index ...