USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 45/60
When switched on, the position controller sets itself for manual operation and only the axis
displays turn on.
In this operating mode, the axis movement can be controlled with the following keys:
or
TO SELECT THE AXIS TO BE MOVED
SLOW FEED AXIS MOVEMENT
SLOW BACK AXIS MOVEMENT
FAST FEED AXIS MOVEMENT
FAST BACK AXIS MOVEMENT
TO DESELECT THE AXIS
Note:
If, during movement, the programmed minimum or maximum measuring length limits are
overcome, the axis stops and the led of the START key begins to flash. This indicates the
overcoming of limits due to low or high speed inertia.
Press the STOP key to cancel the signaling.
MANUAL OPERATION
Summary of Contents for THESI 320
Page 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Page 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Page 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Page 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...