USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 22/60
4.0
Press
to confirm the value and go back
to parameters selection
1 5.0 P 09
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Parameter 10
– SETTING OF MECHANICAL BACKLASH RECOVERY VALUE
If positive, the value of mechanical backlash recovery is executed in positive direction; if
negative, it is executed in negative direction. Whenever backlash recovery is not required,
enter a value of 0.
Example of value setting X axis = 0.0 mm Y axis = 5.0 mm
0.0
Press
to select the parameter
(see PARAM. SELECTION)
0.0 P 10
0.0
Press
and
to select both axes
0.0 P 10
0 0 0 0 0.0
*
Press
to confirm the selection and
enter the X axis setting
0.0 P 10
Enter the desired value and align it to the decimal point displayed.
0.0
Press
to confirm the value and
enter the Y axis setting
0 0 0 0 0.0
*
P 10
Enter the desired value and align it to the decimal point displayed.
0.0
Press
to confirm the value and go back
to parameters selection
5.0 P 10
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Summary of Contents for THESI 320
Page 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Page 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Page 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Page 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...