USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 34/60
Note:
setting at 0 the value of the time of parameter 27, it is possible to operate with a
deceleration based only on the space available for changing speed.
In the figure below, it is possible to find a representation of the acceleration ramp and a
deceleration in the space for changing speed:
Parameter 26
– SETTING OF ACCELERATION TIME
With this parameter it is possible to set the duration of the acceleration ramp, used to
move the axis. The value is expressed in seconds.
The acceleration ramp starts from the output voltage value of 0 V, up to the voltage value
corresponding to the axis movement at high speed (see parameter 23).
Example of value setting X axis = 0.60 seconds Y axis = 0.60 seconds
0.0 0
Press
to select the parameter
(see PARAM. SELECTION)
0.0 0 P 26
0.0 0
Press
and
to select both axes
0.0 0 P 26
0 0 0 0.0 0
*
Press
to confirm the selection and
enter the X axis setting
0.0 0
P 26
Enter the desired value and align it to the decimal point displayed.
0.6 0
Press
to confirm the value and
enter the Y axis setting
0 0 0 0.0 0
*
P 26
t.acc
mm
slow
fast
ok pos
speed change
Summary of Contents for THESI 320
Page 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Page 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Page 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Page 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...