USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 18/60
C n t n 4
Press
to confirm and go back to
parameters selection
P 04
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Parameter 05
– DECIMAL POINT POSITION (0, 1, 2, 3)
With this parameter, it is possible to select the number of decimals that will be shown on
the axis display. Decimals can be 0, 1, 2 or 3.
Example: selecting 1 decimal on X and Y axes
0.0 0
Press
to select the parameter
(see PARAM. SELECTION)
0.0 0 P 05
0.0 0
Press
and
to select both axes
0.0 0 P 05
0.0 0
*
Press
to confirm the selection and
enter the X axis setting
0.0 0 P 05
0.0
*
Press
to select the desired number of
decimals
0.0 0 P 05
0.0
Press
to confirm the value and
enter the Y axis setting
0.0 0
*
P 05
0.0
Press
to select the desired number of
decimals
0.0
*
P 05
0.0
Press
to confirm the value and go back
to parameters selection
0.0 P 05
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0