USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 10/60
KEY USED TO SELECT X AXIS
KEY USED TO SELECT Y AXIS
*
FLASHING VALUE
y
STEADY VALUE
The instrument provides a series of visual signals to support the user during configuration
and use.
Wrong operations are signaled with the following message:
E r r o r
that temporarily appears on the display to inform the operator that the entered key is not
compatible with the current operation.
In case of “overflow” error, i.e. the number of digits displayed is greater than the instrument
counting capacity, the error is shown on the display as:
_ _ _ _ _ _
To exit this situation, enter a compatible position in the “Position Preset” parameter.
In certain situations, the error message will be accompanied by a number, indicating the
cause of the error. For example:
E r r 20
The list of possible errors is provided in the table below:
Error Number
Description
20
Function not present
21
Axis in motion
22
Program unavailable
23
Out of memory
24
Outside measuring length limits
25
Value not allowed
26
No axis selected
90
Internal malfunctioning (request Technical Assistance)
E0
Configuration Error (request Technical Assistance)
Summary of Contents for THESI 320
Page 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Page 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Page 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Page 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...