All the settings for the configuration of the position controller are described below:
Parameter 01
– POSITION PRESET
The parameter is used to set the real positions of the axes.
Example of value setting X= 50.0 mm Y= 200.0 mm
4 0.0
Press
to select the parameter
(see PARAM. SELECTION)
1 2 0.0 P 01
4 0.0
Press
and
to select both axes
1 2 0.0 P 01
0 0 0 0 0.0
*
Press
to confirm the selection and
enter the X axis setting
1 2 0.0 P 01
Enter the desired value and align it to the decimal point displayed.
5 0.0
Press
to confirm the value and
enter the Y axis setting
0 0 0 0 0.0
*
P 01
Enter the desired value and align it to the decimal point displayed.
5 0.0
Press
to confirm the value and go back
to parameters selection
2 0 0.0 P 01
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Parameter 02
– INVERSION OF COUNTING DIRECTION
With this parameter it is possible to invert the counting direction of the axis.
Example: inverting counting direction on Y axis
d i r -
Press
to select the parameter
(see PARAM. SELECTION)
d i r - P 02
d i r -
Press
to select the axis
d i r - P 02
Summary of Contents for THESI 320
Page 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Page 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Page 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Page 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...