USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 17/60
Example: CF value setting = 1.25000 on X and Y axes
1.0 0 0 0 0
Press
to select the parameter
(see PARAM. SELECTION)
1.0 0 0 0 0 P 03
1.0 0 0 0 0
Press
and
to select both axes
1.0 0 0 0 0 P 03
0.0 0 0 0 0
*
Press
to confirm the selection and
enter the X axis setting
1.0 0 0 0 0 P 03
Enter the desired value and align it to the decimal point displayed.
1.2 5 0 0 0
Press
to confirm the value and
enter the Y axis setting
0.0 0 0 0 0
*
P 03
Enter the desired value and align it to the decimal point displayed.
1.2 5 0 0 0
Press
to confirm the value and go back
to parameters selection
1.2 5 0 0 0 P 03
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Parameter 04
– COUNTING MODE (x1, x2, x4)
This parameter allows to select the counting mode of the A and B channels of the encoder.
The counting mode can be direct, double or quadruple.
Note: the parameter setting will be applied on both axes.
Example: quadruple value setting
C n t n 1
Press
to select the parameter
(see PARAM. SELECTION)
P 04
C n t n 1
*
Press
to confirm the selection and
enter its settings
P 04
C n t n 4
*
Press
to select the counting mode
P 04
Summary of Contents for THESI 320
Page 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Page 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Page 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Page 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...