Auto Vascular Calculation Overview
Auto Vascular Calculation enables the LOGIQ 7 to detect and
identify a cardiac cycle. It allows you to assign measurements
and calculations during live timeline imaging, while the image is
frozen, or in CINE. Peak values are detected for venous flow.
During cardiac cycle detection, the system identifies the cardiac
cycle using calipers, vertical bars, and/or highlighting of timeline
data. Use of identifiers is based on measurements and
calculations selected by an operator for the current application.
The system may place calipers at early systolic peak, peak
systole, minimum diastole and end diastole. Vertical bars may
also be placed to indicate the beginning and end of the cardiac
cycle. The peak and/or mean trace may be highlighted. You can
edit the cardiac cycle identified by the system or select a
different cardiac cycle.
You can select the calculations to be displayed in the M&A
Result window during live scanning or on a frozen image. These
calculations are displayed at the top of M&A Result Window
located adjacent to the image. These calculations are
presettable by application which means you can set up the
default calculations to be displayed for each application.
Summary of Contents for LOGIQ 7
Page 4: ...i 2 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 This page intentionally left blank ...
Page 16: ...i 14 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 28: ...Introduction 1 12 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 140: ...Preparing for an Exam 4 28 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 306: ...Scanning Display Functions 6 42 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 418: ...Abdomen and Small Parts 8 18 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 644: ...Cardiology 10 128 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 688: ...Urology 12 8 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 698: ...Pediatrics 13 10 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 882: ...Customizing Your System 16 106 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Page 928: ...Probes and Biopsy 17 46 LOGIQ 7 Online Help Direction 2392536 100 Rev 1 ...
Page 974: ...User Maintenance 18 46 LOGIQ 7 Online Help Direction 2392536 100 Rev 1 ...
Page 983: ...GE Medical Systems ...
Page 984: ...1 2 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...