GE
V
OLUSON
i / V
OLUSON
e
D
IRECTION
KTI106052, R
EVISION
10
S
ERVICE
M
ANUAL
Chapter 1 - Introduction
1-1
Chapter 1
Introduction
Section 1-1
Overview
1-1-1
Purpose of Chapter 1
This chapter describes important issues related to safely servicing the Voluson i / Voluson e.
The service provider must read and understand all the information presented in this manual before
installing or servicing a unit.
Always observe the instructions given in the manual of the peripheral/auxiliary device.
Under consideration of general maintenance requirements a minimum lifetime of 7 years for the
equipment and 5 years for the probes may be expected. To maintain the safety and performance of the
ultrasound system, a regular check (once per year) by authorized personnel is recommended.
1-1-2
Purpose of this Service Manual
This Service Manual provides installation and service information for the Voluson i / Voluson e portable
Ultrasound Scanning System and contains the following chapters:
1.)
Chapter 1 - Introduction
:
Contains a content summary and warnings.
2.)
Chapter 2 - Site-Preparation
:
Contains pre-installation requirements.
3.)
Chapter 3 - Setup Instructions
:
Contains setup and installation procedures.
4.)
Chapter 4 - Functional Checks
:
Contains functional checks that are recommended as part of the
installation, or as required during servicing and periodic maintenance.
5.)
Chapter 5 - Components and Functions (Theory)
:
Contains block diagrams and functional
explanations of the electronics.
6.)
Chapter 6 - Service Adjustments
:
Contains instructions on how to make available adjustments.
7.)
Chapter 7 - Diagnostics/Troubleshooting
:
Provides procedures for running diagnostic or related
routines.
8.)
Chapter 8 - Replacement Procedures
:
Provides disassembly procedures and reassembly
procedures for all changeable Field Replaceable Units (FRU).
9.)
Chapter 9 - Renewal Parts
:
Contains a complete list of field replaceable parts.
10.)
Chapter 10 - Care & Maintenance
:
Provides periodic maintenance procedures.
Table 1-1
Contents in Chapter 1
Section
Description
Page Number
1-1
Overview
1-1
1-2
Important Conventions
1-3
1-3
Safety Considerations
1-8
1-4
Electromagnetic Compatibility (EMC)
1-17
1-5
Customer Assistance
1-18
NOTICE
!! NOTICE:
This Service Manual is valid for
Voluson i / Voluson e
ultrasound systems.
For the sake of simplicity,
descriptions in this manual will be briefly denoted
with Voluson i / Voluson e if no special differentiation is required.
Summary of Contents for H48651KR
Page 2: ......
Page 11: ...GE VOLUSON i VOLUSON e DIRECTION KTI106052 REVISION 10 SERVICE MANUAL ix ZH CN KO ...
Page 44: ...GE VOLUSON i VOLUSON e DIRECTION KTI106052 REVISION 10 SERVICE MANUAL xlii Table of Contents ...
Page 514: ...GE VOLUSON i VOLUSON e DIRECTION KTI106052 REVISION 10 SERVICE MANUAL IV Index ...