GE
V
OLUSON
i / V
OLUSON
e
D
IRECTION
KTI106052, R
EVISION
10
S
ERVICE
M
ANUAL
9-52
Section 9-11 - Probes
9-11-2
Real-Time 4D Volume Probes
Figure 9-23 Real-Time 4D Volume Probes
Table 9-30 Real-Time 4D Volume Probes
Item
Part Name
Part Number
Description
Qty
CRU
FRU
710
RAB2-5RS
KTZ157007
(H46701NA)
Real-time 4D broadband electronic curved-array transducer with a
frequency range of 2-5MHz.
Applications: Abdominal, Obstetrics,
Gynecology, Interventional Radiology
-
Y
1
711
RAB2-6-RS
KTZ302893
(H48681WR)
BT
Version
BT-Version:
Real-time 4D broadband electronic curved-array transducer with a
frequency range of 2-6MHz.
Applications: Abdominal, Obstetrics,
Gynecology, Interventional Radiology
This probe is only applicable at systems with Software CC200 BT’14.
-
Y
1
712
RAB4-8RS
KTZ157074
(H45021L)
BT
Version
BT-Version:
Real-time 4D broadband electronic curved-array transducer with a
frequency range of 4-8MHz.
Applications: Abdominal, OB, Gyn,
Pediatrics, Interventional Radiology
Probe is only applicable at systems with
BT´07
software and higher.
-
Y
1
713
RIC5-9RS
KTZ157006
(H46701RA)
Real-time 4D endocavity broadband electronic curved array transducer
with a frequency range of 5-9MHz.
Applications: Gynecology/Fertility, Obstetrics, Urology
Note:
This probe is only applicable if the option “RIC Probe “ is enabled.
-
Y
1
714
RIC5-9W-RS
KTZ157095
(H48661EF)
Real-time 4D endocavity broadband electronic curved array transducer
with a frequency range of 5-9MHz.
Applications: Gynecology/Fertility, Obstetrics, Urology
Note:
This probe is only applicable if the option “RIC Probe “ is enabled.
-
Y
1
715
RSP6-16RS
*
KTZ157010
(H46701AC)
Real-time 4D broadband electronic linear array transducer with a
frequency range of 6-16 MHz and a scan width of 40 mm.
Applications: Small Parts, Periph.Vascular,
Pediatrics, Urology, Orthopedics
-
Y
1
716
RNA5-9RS*
KTZ157075
H45021LA
BT
Version
BT-Version:
Real-time 4D neonatal broadband electronic curved array transducer
with a frequency range of 5-9MHz.
Applications: Obstetrics, Pediatrics/Neonatology,
Cardiology, Small Parts
Probe is only applicable at systems with
BT´07
software and higher.
-
Y
1
NOTICE
!! NOTICE:
The probes RNA5-9RS and RSP6-16RS aren’t applicable on
Voluson
e
(
marked with
*
in the manual
).
710
711
712
713
714
715
716
Summary of Contents for H48651KR