Installation
Erection general procedures
GE Information
07- 2016
L31- 003EN/03
2/6
Preparing and installing static seals
Necessary products
List of the Grid Solutions products necessary for the installing :
Grid
Solutions
reference
Diagram
Designation
- 01861262
Can of ISOPROPANOL (1l)
- 01835265
MOLYKOTE 111 (100g tube)
Process
The table below gives the steps of installing static seals :
Step
Action
Comment
1
Clean bearing grooves and sur-
faces using ISOPROPANOL.
2
Rid the seal of all foreign bodies
such as paintbrush bristles or fil-
ings...
Remove (where applicable) the
color identification point with fin-
gernail, never with a sharp instru-
ment.
Check the condition of the seal
which should present no
scratches or deformation (it
should be neither flattened,
stretched, nor broken).
3
Lightly lubricate the seal by hand
using MOLYKOTE 111 grease.
Do not use a brush to do this.
Eliminate excess grease by
squeezing the seal between
fingers, leaving only a thin layer
on the entire surface.
4
Put the seal(s) in place.
5
Lubricate both bearing surfaces
with MOLYKOTE 111.
Fill the residual volume of the
seal’s outside groove with grease.
Do not put grease on the inside
surface.
Only seals are
greased in this
zone
Greasing zone
Greasing zone
Summary of Contents for GL317D
Page 206: ...Grid Solutions This page is intentionally blank...
Page 212: ...Grid Solutions This page is intentionally blank...
Page 216: ...Grid Solutions This page is intentionally blank...
Page 220: ...Grid Solutions This page is intentionally blank...
Page 295: ...GE Information This page is intentionally blank...
Page 296: ......