18
GC32FLEX
GC32FLEX/TSI SAFETY AND OPERATION MANUAL
GETTING TO KNOW YOUR CRIMPER
FULL OPERATING PROCEDURE OVERVIEW
Power Unit Selection and Set Up
Select a suitable 10,000 PSI power unit and connect to the 3/8” NPT
Input of the Head.
See page 12 for more details.
e-Crimp™ setting selection on EDI
Search e-Crimp™ on the included tablet or mobile application for the
assembly you wish to crimp. The EDI setting will be displayed after
selecting an assembly.
Twist the knob on the EDI to match the e-Crimp™ setting specified.
See page 13 for more details.
Load Dies
Load the required dies as specified by e-Crimp™ into the machine using
the Quick Change Tool.
See page 40 for more details.
Crimp Hose Assembly
Place the hose assembly into the crimper (follow procedure for correct
hose assembly process page 43).
Activate the power unit and release when the light on the EDI turns red
(see silver indicator for notice).
See page 15 for more details on EDI Operation.
Measure Assembly
Remove the crimped assembly and measure across the flats as per
correct hose measuring procedure (See page 44 for details).
If the assembly is not within the specified tolerance discard the fitting
and follow the EDI calibration procedure (Page 16 & 17) for next crimp.