32
GC32FLEX TSI POWER UNIT
GC32FLEX/TSI SAFETY AND OPERATION MANUAL
GETTING TO KNOW YOUR CRIMPER
INSTALLATION -
Refer to IFC WI1068 (Included) for more detailed set-up/installation instructions.
Move and Position
Carefully move the power unit over the right side of the crimper
and slowly lower.
Note:
The tray area must be clear and the crimper must be in the
heads back position.
Remove the Dial Indicator from the machine if it is attached on
either the left or right side of the head.
Sensor Arm
Ensure the sensor arm is behind the crimper head and does not
connect with the piston plate.
The sensor arm is connected to the crimper via a magnet.
Secure
Detach the sling and move the power unit so that it lines up with
4 x M8 holes on the tray.
Use the 4 x M8 x 10mm BHSHCS provided and 5mm Hex key to
secure the power unit to the tray.
Sensor Arm
Move the sensor arm towards the rear of the piston plate.
Because it is magnetic, it will attach itself to the surface.
Note:
Do not force the sensor arm in any way it should slide freely
at all times.