12
GC32FLEX
GC32FLEX/TSI SAFETY AND OPERATION MANUAL
GETTING TO KNOW YOUR CRIMPER
POWER UNIT
Power Unit Selection
Any Hydraulic power unit capable of 10,000 PSI can be used to
run the machine. These can range from a hand pump through to
pneumatic assisted or battery operated pumps.
See your Gates Representative for more details.
Power Unit Placement
Ensure the power unit is positioned next to the crimper head in
designated area. Follow the power unit instructions at all times
during operation.
If the power unit is electrically operated check the voltage and
frequency on the serial plate.
Ensure it is in a suitable location.
Secure Power Unit
Place the supplied strap over the power unit and through the base
slots to secure it to the tray.
Connect Power Unit Crimper
Connect the supplied hose to the chosen power unit.
Note: both ends of hose are 3/8” NPT Male.
Connect the other end of the hose to the crimper head using a
15/16” wrench.
The fitting in the Crimper head is a 3/8” NPT Swivel connection.
Hold hex on hose end with 3/4” Spanner while tightening swivel
connection with 15/16” Spanner.
Crimper Ready
The crimper is now ready for operation.
Ensure that the machine does not go over 10,000 PSI at any
time during operation. Use of an External Power unit with an
internal relief valve is strongly recommended. Crimp speed is
determined by the external power unit when in use.
!