Page D-22
G900X/G950 Installation and Maintenance Manual – Troubleshooting
Revision D
190-00719-00
GIA2 RS-232 (continued)
Channel LRU Indicator
Status
GIA2/GTX 33 data path is functioning correctly.
GIA2/GTX33 data path is not functioning correctly.
•
Check PFD Alert Window for GIA or GTX
configuration or software error messages.
Correct any errors before proceeding.
•
Swap GIA1 and GIA2, reconfigure both GIA’s
to their new locations to confirm if the problem
is in the original GIA2.
−
Replace original GIA2 if box turns green
after swapping units.
•
Check the GIA2/GTX 32/33 interconnect
wiring and connector pins for faults.
•
Replace GTX 32/33.
CHNL 5
GTX 33
GIA2/GTX 33 data path functionality is unknown.
Reload GIA2 configuration files.