Page 13-8
G900X/G950 Installation and Maintenance Manual – Non LRU Specific Installation Information
Revision D
190-00719-00
8.
Guidelines for terminating the newly cutoff Flat Braid(s) (item 6) with insulated ring terminals
(item 9):
•
Each tapped hole on the Shield Block (item 2) may accommodate only two ring terminals
(item 9).
•
It is preferred that only two Flat Braid(s) (item 6) be terminated per ring terminal. Two
Flat Braids per ring terminal will necessitate the use of a Ring terminal, #8, insulated, 14-
16 AWG (MS25036-153).
•
If only a single Flat Braid is left or if only a single Flat Braid is needed for this connector
a Ring terminal, #8, insulated, 18-22 AWG (MS25036-149) can accommodate this single
Flat Braid.
•
If more braids exist for this connector than two per ring terminal, it is permissible to
terminate three braids per ring terminal. This will necessitate the use of a Ring terminal,
#8, insulated, 10-12 AWG (MS25036-156).
9.
Repeat steps 2 through 8 as needed for the remaining shielded cables.
10.
Terminate the ring terminals to the Shield Block (item 2) by placing items on the Pan Head Screw
(item 10) in the following order: Split Washer (item 11), Flat Washer (item 12) first Ring
Terminal, second Ring Terminal (if needed) before finally inserting the screw into the tapped
holes on the Shield Block. Do not violate the guidelines presented in Step 8 regarding ring
terminals.
11.
It is recommended to wrap the cable bundle with Silicone Fusion Tape (item 13) (GPN: 249-
00114-00 or a similar version) at the point where the backshell strain relief and cast housing will
contact the cable bundle.
NOTE
Choosing to use this tape is the discretion of the installer.
12.
Place the smooth side of the backshell strain relief (item 14) across the cable bundle and secure
using the three screws (item 15). Warning: Placing the grooved side of the strain relief across the
cable bundle may risk damage to wires.
13.
Attach the cover (item 16) to the backshell (item 1) using the two screws (item 17).