Page C-48
G900X/G950 Installation and Maintenance Manual – PICP & Warranty Registration
Revision D
190-00719-00
C.2.21.3 GEA Failure Test
Step Desired
Result
GEA Failure Conditions:
1. Remove power from the GEA.
2. Check for desired results.
3. Restore power to the GEA.
GEA Failure – For a GEA failure, the following shall
occur:
9
All EIS gauges are invalid
C.2.21.4 GMA Failure Test
Step Desired
Result
GMA Failure Conditions:
1. Remove power from the GMA.
2. Check for desired results.
3. Restore power to the GMA.
GMA Failure – For a GMA failure, the following shall
occur:
9
“GMA1 FAIL – GMA1 is inoperative” alert
message on the PFD
9
No
audio
C.2.21.5 GTX Failure Test
Step Desired
Result
GTX Failure Conditions:
1. Remove power from the GTX.
2. Check for desired results.
3. Restore power to the GTX.
GTX Failure – For a GTX failure, the following shall
occur:
9
“TRAFFIC FAIL – Traffic device has failed” alert
message on the PFD
9
“XPDR FAIL” message on the PFD
9
Invalid transponder field