Page 13-4
G900X/G950 Installation and Maintenance Manual – Non LRU Specific Installation Information
Revision D
190-00719-00
13.2.1 Shield Termination Technique – Method A.1 (Standard)
1.
Attach the Shield Block(s) (item 2) to the backshell (item 1) by inserting the flathead screws
(item 3) through the holes on the Shield Block and threading into the tapped holes on the
backshell (item 1) (see Figure 13-1). The appropriate number of Shield Block kits will be
included in the particular LRU connector kit, but Table 13-4 lists possible configurations.
Table 13-4. Possible Shield Block Arrangements
Backshell Assembly
Shield Block
Pin Count
(Std./High)
GPN
GPN Arrangement
(9/15)
011-00950-
00
011-01169-00
One
(15/26)
011-00950-
01
011-01169-00
One
One
(25/44)
011-00950-
02
011-01169-00
Two
(if needed)
(37/62)
011-00950-
03
011-01169-01
One
(50/78)
011-00950-
04
011-01169-01
One
Figure 13-2. Method A.1 for Shield Termination