Page 5-18
G1000/DA40 System Maintenance Manual
Revision 6
190-00303-03
5.8.5 GIA Cooling Alerts
Failure Message
Cause
Solution
GIA1 COOLING – GIA1
temperature too low.
GIA1 operating temperature is too
low.
Allow unit to warm up.
GIA2 COOLING – GIA2
temperature too low.
GIA2 operating temperature is too
low.
Allow unit to warm up.
GIA1 COOLING – GIA1 over
temperature.
GIA1 has exceeded its operating
temperature range.
Check Avionics Fan for proper operation.
Replace GIA1.
If problem persists contact Garmin.
GIA2 COOLING – GIA2 over
temperature.
GIA2 has exceeded its operating
temperature range.
Check Avionics Fan for proper operation.
Replace GIA2.
If problem persists contact Garmin.
5.8.6 GIA Configuration Alerts
Failure Message
Cause
Solution
MANIFEST – GIA1 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in GIA1.
MANIFEST – GIA2 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in GIA2.
See Section 7.3.1 for GIA 63 Software
Loading procedure.
GIA1 CONFIG – GIA1
configuration error. Config service
req’d.
GIA2 CONFIG – GIA2
configuration error. Config service
req’d.
The system has detected a GIA
configuration mismatch. If GIAs
are not properly configured after
being swapped/replaced, this
message appears.
See Section 7.3.2 for GIA 63
Configuration Loading procedure.