G1000/DA 40 System Maintenance Manual
Page 7-21
190-00303-03
Revision 6
7.6
GDC 74A Air Data Computer
Original GDC 74A is Reinstalled
No software or configuration loading is required if the removed GDC 74A is re-installed. Continue to the
GDC 74A Test procedure.
New GDC 74A is Installed
If a new GDC 74A (new serial number) is installed, the correct software and configuration files must be
loaded to the unit. Continue to the GDC 74A Software Loading procedure.
7.6.1 GDC 74A Software Loading
1.
Insert the correct G1000/DA 40 SW Loader Card (see Appendix A) into top slot of PFD.
2.
Start the G1000 system in Configuration mode.
3.
Go to the Software Upload page using the FMS knob.
4.
Highlight the GDC software file. Ensure that GDC to GIA data path appears in the LRU field as
shown:
5.
Press the LOAD softkey.
6.
Select YES and press the ENT key to acknowledge the following prompt:
7.
The software for the GDC 74A Air Data Computer begins to load. Monitor the upload status as it
progresses:
8.
After the files finish loading, press ENT to acknowledge the following prompt:
9.
Check the SUMMARY field to ensure the load is ‘COMPLETE’.
10.
Continue to the GDC 74A Configuration Loading procedure.