![Garmin Diamond DA40 Maintenance Manual Download Page 85](http://html1.mh-extra.com/html/garmin/diamond-da40/diamond-da40_maintenance-manual_4182198085.webp)
G1000/DA40 System Maintenance Manual
Page 5-23
190-00303-03
Revision 6
5.12
GDC 74A Troubleshooting
5.12.1 GDC Alerts
Failure Message
Cause
Solutions
MANIFEST – GDC1 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in GDC 74A.
•
Reload software. See
Section 7 for GDC 74A Software
Load Procedure.
BACKUP PATH – Airdata using
backup data path.
The GDC 74A is using a backup
ARINC 429 data path.
Check ARINC 429 configuration
settings at GDU and GIA page
groups:
9
If configuration is not correct,
reconfigure GIA or GDU as
described in Section 7.
Check wiring.
Replace PFD1 with a known good unit,
to verify location of problem:
9
If problem persists, replace the
GDC 74A.
9
If problem does not persist,
replace PFD1.
GDC 74A
ARINC 429
ETHERNET
ETHERNET
ETHERNET
ETHERNET
ARINC 429
ETHERNET
ETHERNET
ARINC 429
ARINC 429
No. 1
No. 2
GIA 63
GIA 63
Primary Data Path
Secondary Data Path
Third Data Path
Fourth Data Path
GDC 74A
GDC 74A
GDC 74A
No. 1
GDU 1040
PFD
No. 1
GDU 1040
MFD
No. 1
GDU 1040
PFD
No. 1
GDU 1040
MFD
No. 1
GDU 1040
PFD
No. 1
GDU 1040
MFD
No. 1
GDU 1040
PFD
No. 1
GDU 1040
MFD
Figure 5-11. GDC 74A Data Paths
Summary of Contents for Diamond DA40
Page 1: ...190 00303 03 January 2007 Revision 6 G1000 System Maintenance Manual Diamond DA 40...
Page 130: ......
Page 137: ...G1000 DA40 System Maintenance Manual Page A 3 190 00303 03 Revision 6 A 4 Parts List...
Page 138: ...G1000 DA40 System Maintenance Manual Revision 6 190 00303 03 Page A 4...