Page 7-32
G1000/DA40 System Maintenance Manual
Revision 6
190-00303-03
15.
Repeat the turn-and-stop process until the PFD advises that a successful calibration is complete.
The GRS 77 AHRS then enters its normal operational mode. Press the ENT button on the PFD to
conclude this procedure.
7.7.6 Procedure C: Engine Run-Up Vibration Procedure
Calibration Procedures A and B are not required prior to this procedure.
1.
Start both displays in normal mode.
2.
Start the aircraft engine following the procedures in the G1000/DA40 Airplane Flight Manual
Supplement.
3.
After aircraft engine startup, taxi the aircraft to a suitable area for engine run-up.
4.
Restart both displays in configuration mode.
5.
On the MFD, select the GEA page group. At the Engine Data page, monitor engine performance
during the procedure:
6.
Go to the GRS Page Group on the PFD.
7.
Select the GRS/GMU Calibration page and enter the following softkey password:
a)
9
b)
10
c)
11
d)
12 (Far Right softkey)