Invalid Data Field
Associated
LRU(s)
Solution
ATTITUDE FAIL
GRS 77
Check GRS ARINC 429 configuration settings for the PFD,
MFD, GIA1, and GIA2.
Replace defective GRS 77.
HDG FAIL
GRS 77 &
GMU 44
Replace the GMU 44 with a known good unit:
9
If problem persists, replace defective GRS 77.
GRS 77 &
GMU 44
If this message persists, perform AHRS calibration procedures
as described in Section 7.7.3.
Engine/Airframe Sensors
(All Invalid)
GEA 71
Check GEA 71 RS-485 configuration settings for GIA1 and
GIA2.
Reconfigure the GEA 71 per Section 7.4.2.
Check GEA – GIA1 and GEA – GIA2 Wiring.
Replace defective GEA 71.